Functioning
Function: The correct anchor selection is based on the thickness of the panel. When tightened with the installation pliers, the anchor legs fold up against the back of the panel and support the anchor. The large contact radius distributes the tensile forces and gives the Upat UH its good holding values. The anchor remains in its position even when the screw is removed
Installation: The Upat cavity anchor UH is installed in pre-positioning mounting. Efficient installation with installation pliers: Set borehole, drive in cavity anchor. Expand cavity anchor with installation pliers. Position attachment. Screw in screw - done. Pragmatic installation without installation pliers: Set borehole, drive in cavity anchor. Position attachment. Expand cavity anchor by screwing in the screw - done
Tools: Drill, drill machine, hammer, setting tool (UHZ), optional screwdriver/electric screwdriver