ETA-approval | |
Drill diameter ( d0 ) | 14 mm |
Min. drill hole depth for through fixings ( h2 ) | 115 mm |
Screw dimension ( ds x ls ) | 16.0x100 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 65 / 35 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 85 / 15 mm |
Nominal embedment depth / thickness of fixture | — |
Drive | SW 21 |
Seismic-Approval | — |
Fire resistance | R120 |
Amount | 20 pcs |
GTIN (EAN-Code) | 4000657034140 |
ETA-approval | |
Drill diameter ( d0 ) | 14 mm |
Min. drill hole depth for through fixings ( h2 ) | 140 mm |
Screw dimension ( ds x ls ) | 16.0x125 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 65 / 60 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 85 / 40 mm |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 115 / 10 mm |
Drive | SW 21 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 10 pcs |
GTIN (EAN-Code) | 4000657034157 |
ETA-approval | |
Drill diameter ( d0 ) | 14 mm |
Min. drill hole depth for through fixings ( h2 ) | 165 mm |
Screw dimension ( ds x ls ) | 16.0x150 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 65 / 85 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 85 / 65 mm |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 115 / 35 mm |
Drive | SW 21 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 10 pcs |
GTIN (EAN-Code) | 4000657034164 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 65 mm |
Screw dimension ( ds x ls ) | 10.0x55 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 5 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture | — |
Drive | TX40 / SW 13 |
Seismic-Approval | — |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032191 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 80 mm |
Screw dimension ( ds x ls ) | 10.0x70 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 20 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 5 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032207 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 90 mm |
Screw dimension ( ds x ls ) | 10.0x80 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 30 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 15 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032214 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 100 mm |
Screw dimension ( ds x ls ) | 10.0x90 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 40 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 25 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032221 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 110 mm |
Screw dimension ( ds x ls ) | 10.0x100 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 50 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 35 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032245 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 120 mm |
Screw dimension ( ds x ls ) | 10.0x110 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 60 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 45 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032252 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 140 mm |
Screw dimension ( ds x ls ) | 10.0x130 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 80 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 65 mm |
Drive | TX40 / SW 13 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657032269 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 70 mm |
Screw dimension ( ds x ls ) | 10.0x60 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 10 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture | — |
Drive | TX40 |
Seismic-Approval | — |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034171 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 90 mm |
Screw dimension ( ds x ls ) | 10.0x80 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 30 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 15 mm |
Drive | TX40 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034188 |
ETA-approval | |
Drill diameter ( d0 ) | 8 mm |
Min. drill hole depth for through fixings ( h2 ) | 100 mm |
Screw dimension ( ds x ls ) | 10.0x90 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 50 / 65 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 65 / 25 mm |
Drive | TX40 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034195 |
ETA-approval | |
Drill diameter ( d0 ) | 10 mm |
Min. drill hole depth for through fixings ( h2 ) | 75 mm |
Screw dimension ( ds x ls ) | 12.0x65 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 55 / 10 mm |
Nominal embedment depth / thickness of fixture | — |
Nominal embedment depth / thickness of fixture | — |
Drive | TX50 |
Seismic-Approval | — |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034393 |
ETA-approval | |
Drill diameter ( d0 ) | 10 mm |
Min. drill hole depth for through fixings ( h2 ) | 90 mm |
Screw dimension ( ds x ls ) | 12.0x80 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 55 / 25 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 65 / 5 mm |
Nominal embedment depth / thickness of fixture | — |
Drive | TX50 |
Seismic-Approval | — |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034423 |
ETA-approval | |
Drill diameter ( d0 ) | 10 mm |
Min. drill hole depth for through fixings ( h2 ) | 105 mm |
Screw dimension ( ds x ls ) | 12.0x95 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 55 / 40 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 65 / 30 mm |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 85 / 10 mm |
Drive | TX50 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034454 |
ETA-approval | |
Drill diameter ( d0 ) | 10 mm |
Min. drill hole depth for through fixings ( h2 ) | 110 mm |
Screw dimension ( ds x ls ) | 12.0x100 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 55 / 45 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 65 / 35 mm |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 85 / 15 mm |
Drive | TX50 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034461 |
ETA-approval | |
Drill diameter ( d0 ) | 10 mm |
Min. drill hole depth for through fixings ( h2 ) | 130 mm |
Screw dimension ( ds x ls ) | 12.0x120 mm |
Nominal embedment depth / thickness of fixture ( hnom1 / tfix ) | 55 / 65 mm |
Nominal embedment depth / thickness of fixture ( hnom2 / tfix ) | 65 / 55 mm |
Nominal embedment depth / thickness of fixture ( hnom3 / tfix ) | 85 / 35 mm |
Drive | TX50 |
Seismic-Approval | C1 / C2 |
Fire resistance | R120 |
Amount | 50 pcs |
GTIN (EAN-Code) | 4000657034478 |